ESSEX PB&R VRU+

Victim Rescue Unit Plus

Click to download the >> VRU+ Brochure << (.PDF Format)

Donning

Operation

Packaging

Specifications

Warranty

VRU+ Manual

VRU+ MSDS

Request chem/bio
test data
*

FAQs on the new VRU+

Essex VRU+ Benefits

  • Chem/bio protection*
  • Up to 60 minutes of protection
  • Dons & doffs in seconds
  • Resists high heat, flames & fumes
  • Portable & compact
  • Allows two-way communication
  • Provides mobility & 360-degree visibility
  • Requires no special fitting

The Essex PB&R VRU+ is a self-contained protective breathing device intended for trained individuals in rescue and escape situations from chem/bio agents, fire, smoke, and toxic fumes.*

Want More Information?
For more information on the VRU+, click here

Want to order?
Email: >>Click Here<<

Or, phone us at:
1-800-296-7587 (US) or
1-314-351-6116 (Int’l.)


Donning the VRU+

The VRU+ donning steps are as follows:

  1. Open pouch
  2. Remove sealed VRU+
  3. Tear open package
  4. Remove VRU+
  5. Hold the bottle and activate the oxygen flow
  6. Put hands in neck seal
  7. Pull the VRU+ over your head

Operation

The VRU+ is a closed circuit rebreather system. Oxygen flows into the hood and is breathed and rebreathed by the user. The oxygen concentration inside the hood may reach 60%, depending on workload, and will then decrease for the duration of use. The oxygen flow is begun by semi-automatic activation.

Oxygen was selected as the breathable atmosphere because of weight and volume considerations. During respiration, oxygen is removed from the air and converted to carbon dioxide, which is then exhaled back into the air. If compressed air were used instead of oxygen, the air inside the hood would need to be constantly replenished to maintain the oxygen content at a life-supporting level. Because the VRU+ uses pure, aviator's grade oxygen, the exhaled air can be rebreathed once the carbon dioxide is removed. A typical industrial escape hood that relies on compressed air contains 350 L of air at 3,000-psi pressure. The VRU+ contains 18 L of oxygen at 3,000-psi pressure. The typical industrial escape hood weighs over 6 pounds. The VRU+ weighs just 1 1/2 pounds.

Carbon dioxide is a natural byproduct of respiration. Because the VRU+ is a closed circuit system, it is necessary to remove the carbon dioxide that builds up inside the hood. This is accomplished with a unique, patented passive scrubber. The carbon dioxide will be kept below 4% for the duration of use, but may reach a peak of 7% momentarily.

Duration of Use: All emergency rescue and escape situations are different, and it is not possible to provide an exact duration time for all situations. Also, the size of the VRU+ user will affect usable life, with heavier individuals consuming oxygen more rapidly. However, for an average male, the following typical escape situations are useful in predicting how long the VRU+ will last:

Sitting, waiting to be rescued; Up to 60 minutes
Waiting 17 minutes to be rescued, then rapid evacuation; Up to 21 minutes
Moderate walking (3 mph); Up to 18 minutes
Evacuation of a 110 Story Building; Up to 20 minutes
Rapidly walking, on a flat, out of a building; Up to 8 minutes
Rapidly walking up 15 flights of stairs; Up to 3 minutes


Packaging

The VRU+ is folded and sealed inside a multi-laminate pouch, which, in turn, can be packaged a variety of ways depending on your requirements including inside a fire resistant container. Containers are available with carabineers for carrying the VRU+ on web gear or belt. In addition, the VRU+ can be easily stored or mounted for industrial settings and can be donned in the near zero visibility atmosphere that may accompany a fire.

Description-VRU+ Units Model #
VRU+ Semi-Automatic Activation with Window MR-10060N
VRU+ Semi-Automatic Activation with Window [SS] MR-10061NSS
VRU+ Trainer w/ Semi-Automatic Activation MR-10027N


Specifications
Source of Breathable Air
Bottle of 100% aviators grade compressed oxygen
Bottle has overpressure protection to prevent rupture
Carbon Dioxide Control
Patented passive scrubber
Stowage Temperature Range
From 185° F to -20°F
Working Temperature Range
From 120° F to 5°F
Oxygen Activation
Semi-Automatic
Method of Inspection
Visual
Service & Shelf Life
10 years and 6 months
Oral Communications
Effective at 4 yards
Thermal Resistance
Radiant heat: 1.0 BTU / ft2 for up to 60 seconds
Dripping thermoplastics: 390° F
Transient flame: 1800° F for 5 seconds
Materials of Construction
The patented hood is made from multiple layers of PFA film and Polyimide film
Polyimide film for high heat resistance
The patented neck seal is made from a very elastic, high strength silicone and process treated to protect against chem/bio agents*
Packaging
Fire-resistant Fabric pouch for versatility of carrying modes-pocket, belt web gear
Weight
Vacuum pouch alone: 1.5 lbs.
Stowage Pouch & Unit: 2.0 lbs.
Size
VRU+ in Fabric Soft Pack - 7½" x 9½" x 2"


Statement of Warranty for Victim Rescue Unit (VRU) and Victim Rescue Unit - Plus (VRU+)

Essex P. B. & R. Corp. warrants that: (1) The Essex Victim Rescue Unit (VRU) and Victim Rescue Unit - Plus (VRU+) (hereinafter referred to as the “unit”) will remain free from defects in material and workmanship, whether patent or latent, for up to the replace by date which is a period of ten (10) years and six (6) months from the date of manufacture when properly stowed in containers supplied or approved by Essex P. B. & R. Corp.

For those units equipped with a humidity indicator, the loss of vacuum in the inner packaging does not render the unit unserviceable. Units with barrier pouches that have lost vacuum remain serviceable as long as the humidity indicator remains blue. Although if a unit is found to have a damaged barrier pouch, e.g. cut, puncture or other damage, the unit should be pulled from service and sent back for repair at the customer’s expense.

The liability of Essex P. B. & R. Corp. for any defect in any unit, and the sole and exclusive remedy of the buyer, shall be limited to the repair or replacement of the defective unit, or a refund of the original purchase price (pro-rated in proportion to the ten (10) year and six (6) month warranty) at the sole discretion of Essex P. B. & R. Corp. The obligation to repair, replace, or provide a pro-rated refund shall terminate ten (10) years and six (6) months after the date of manufacture of the unit.

This warranty is in lieu of all other warranties and representations, expressed or implied, and all other obligations and liabilities of Essex P. B. & R. Corp. Correction of defects, in the manner and for the period of time provided above, shall constitute fulfillment of all liabilities of Essex P. B. & R. Corp. whether based on warranty, tort, contract or otherwise. Under no circumstances shall Essex P. B. & R. Corp. be liable for any punitive, special, incidental or consequential damages.

This warranty shall not apply to any unit that has been stowed in an unauthorized container, which has been repaired or altered by anyone other than Essex P. B. & R. Corp., or which has been subject to misuse due to negligence or accident, or the failure to use the unit in accordance with the Product’s Manual supplied by Essex P. B.& R. Corp.

THE FOREGOING WARRANTIES ARE IN LIEU OF ALL WARRANTIES, EITHER EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY, NON-INFRINGEMENT, OR FITNESS FOR A PARTICULAR PURPOSE, AND OF ANY OTHER OBLIGATION ON THE PART OF ESSEX P. B. & R. CORP.